Returnable Cylinders
| |
Unit |
|
|
|
| Solkane® 227 pharma |
kg/lb |
12/26 |
70/154 |
1,050/2,314 |
| Solkane® 134a pharma |
kg/lb |
10/22 |
60/132 |
900/1,984 |
| Capacity approx. |
l |
10 |
61 |
910 |
| Height incl. protection cap approx. |
cm |
100 |
106 |
- |
| Height excl. protection cap approx. |
cm |
81 |
92,5 |
- |
| Length approx. |
cm |
- |
- |
223 |
| Diameter across beads approx. |
cm |
14 |
32 |
86 |
| Tare weight approx. |
kg |
13 |
30 |
500 - 550 |
| Test pressure |
bar (abs) |
300 |
43 |
44 |
ISO Tank Containers and Roadtankers
|
ISO Tank Container
Solkane® 227 pharma:
approx. 17,000 kg/37,478 lb
Solkane® 134a pharma:
approx. 16,500 kg/36,333 lb |
|
Roadtanker
Solkane® 227 pharma:
approx. 18,000 kg/39,683 lb
Solkane® 134a pharma:
approx. 16,000 kg/35,274 lb |
Classification and Transport Information
| |
|
Solkane® 227 pharma |
|
Solkane® 134a pharma |
| Chemical Name |
|
1,1,1,2,3,3,3,-
Heptafluoropropane |
|
1,1,1,2-
Tetrafluoroethane |
| Chemical Formula |
|
CF3-CFH-CF3 |
|
CF3-CH2F |
| CAS-No. |
|
431-89-0 |
|
811-97-2 |
| EG-No. (EINSEC) |
|
207-079-2 |
|
212-377-0 |
| UN No. |
|
3296 |
|
3159 |
| ECC Labelling |
|
Not dangerous according to
Dir. 92/32/EEC |
|
Not dangerous according to
Dir. 92/32/EEC |
| Hazard Label |
|
Compressed gas, non-flammable,
Class 2, Figure 2 |
|
Compressed gas, non-flammable
Class 2, Figure 2 |
Technical Service ITA
Planning, Installation and Maintenance of Storage Tank Farms for Solkane®
Our technical service has been active since 1963. It has installed approx. 1,500 tank plants, 50 small tank plants and 3,000 MTC facilities. Support has been provided during around 5,000 technical inspections. Vessels up to 100 m3 volume can be installed.
Full Service
- Consulting
Information exchange with clients on site and via other communications tools
- Targets
Economical solutions compliant with standards and regulations
- Tank Farm Planning and Construction
Services include component sourcing, erection and foundation drawings, enquiries, procurement, forwarding, installation in consultation with the client, final check, commissioning and documentation
- Assistance During Technical Approval
Tank evacuation, opening, measuring oxygen concentration, support officials, closing, leak testing, refilling, commissioning – all without product losses and environmental contamination
- Conversion
Converting existing tanks to new Solkane types
- Pipe Installation
Expanding, modifying, repairing, installing new fittings
- Emptying/Disposal, Shut Down
During shut downs: disposal of residual volumes with certificates in cooperation with our partner company
- Operations Assistance
Fast rectification of operational difficulties, minimization of shut down periods
|